CABLE FIBRE OPTIC DLC-DLC 10M/YELLOW N122.4LLY10 AGINODE

Cod ELKO
1427831
Aginode LANmark-OF Slimflex Patch Cord DLC/UPC - DLC/UPC SM LSZH Yellow 10 m. Cable length: 10 m, Cable type: SMF, Fibre optic type: G.657.A1, Connector 1: 2x LC, Connector 2: 2x LC, Core diameter: 9 µm, Full duplex
SPECIFICAȚII
Model
N122.4LLY10
Model name
LANmark-OF Slimflex Patch Cord DLC/UPC - DLC/UPC SM LSZH Yellow 10 m
Features
Cable type
SMF
Cable length
10 m
Fibre optic type
G.657.A1
Cable shape
Round
Connector 1
2x LC
Connector 2
2x LC
Connector 1 gender
Male
Connector 2 gender
Male
Connector polish type
UPC
Product colour
Yellow
Full duplex
Yes
Core diameter
9 µm
Fiber mode structure
Single-mode
Insertion loss
0.25 dB
Return loss
50 dB
Jacket material
Low smoke zero halogen (LSZH)
Polarity
A/B
Brand compatibility
Any brand
Plug and Play
Yes
Doesn't contain
Halogen
Operating temperature (T-T)
-10 - 50 °C
Weight & dimensions
Cable diameter
2 mm
Bending radius
10 mm
Quantity per pack
1 pc(s)

Guarantees and installation
Aginode's LANmark-OF optical fibre patch cords have been designed for indoor applications in support of high speed protocols.
High speed protocols supported include, but are not limited to Ethernet 1GBase-LX and Ethernet 10GBase-LR.
Details on the supported distances can be found in the LANmark-OF warranty modules.

Typical installation environments are:
- Cabinets to connect patch panels to active equipment.
- Cross connects in data centres.
- Suitable for use in the work area to connect the workstation to the wall outlet (Fibre To The Desk).

Characteristics
- Patch cord cable is according to IEC 60794-2-50
- Maximum insertion loss according to IEC 61300-3-4: 0.25 dB
- Typical insertion loss: 0.1 dB
- Minimum return loss according to IEC 61300-3-6 for LC/UPC: 50 dB
- Minimum return loss according to IEC 61300-3-6 for LC/APC: 65 dB
- Duplex LC-LC, duplex LC-SC and duplex SC-SC patch cords have a duplex cable construction with a diameter of 2 X 2.0 mm.
- Short connector boots of 19mm
- Small bend radius: 10 mm
- A traceability label is added close to the connector

Fibre type
The LANmark-OF SM patch cords have LANmark-OF SM GIGAliteFLEX fibre inside. These fibres are bend insensitive and compliant to ITU-T G.657.A1 and to IEC 60793-2-50, fibre model B6.a1. The pigtail jacket of the singlemode pigtails is yellow.

Design
Aginode's LANmark-OF patchcords designed according to the "Cross-Over" wiring principle to improve field installation (A1-B2, B1-A2). This conforms to the requirements of IEC 11801 and EN 50174-1:2009.

The "butterfly" duplex clip allows to change the polarity on site easily by simply removing the 2 connectors and put them in a reverse order back into the same clip. No tool is required for this polarity change.

  • Optical fiber patch cords
  • LANmark-OF singlemode performance
  • GIGAliteFLEX bend insensitive fibre
  • For use in cabinets and workplaces