Peste 40 000 de produse IT și electronice de consum de la producători de top

NET GATEWAY MODBUS 1PORT/IMG-3105AT PLANET

Cod ELKO
1468097
PLANET IMG-3105AT. Product colour: Blue, Enclosure material: Metal, Mounting type: DIN-rail/Wall mounting. Supported network protocols: LLDP. Networking standards: IEEE 802.3, IEEE 802.3u. Security algorithms: SNMP, SNMPv2c, SNMPv3. Serial interface type: DB9
SPECIFICAȚII
Design
Mounting type
DIN-rail/Wall mounting
Product colour
Blue
Enclosure material
Metal
LED indicators
Yes
Enclosure International Protection (IP) code
IP30
Control display unit
No
Protocols
DHCP client
Yes
Supported network protocols
LLDP
Network
Networking standards
IEEE 802.3/IEEE 802.3u
Flow control support
Yes
Security algorithms
SNMP/SNMPv2c/SNMPv3
Ports & interfaces
DC-in jack
Yes
Fixed SFP ports quantity
1
Serial interface type
DB9
Management features
Quality of Service (QoS) support
Yes
Reset button
Yes
Syslog
Yes
Web-based management
Yes
Power
Power consumption (max)
2.88 W
Input voltage
9 - 48 V
Heat dissipation
9.83 BTU/h
Electrostatic Discharge (ESD) protection
Yes
Weight & dimensions
Depth
87.8 mm
Height
135 mm
Width
32 mm
Weight
392 g
Packaging content
Manual
Yes
Quick installation guide
Yes
Operational conditions
Operating temperature (T-T)
-40 - 75 °C
Storage temperature (T-T)
-40 - 85 °C
Operating relative humidity (H-H)
5 - 95 %
Compliance certificates
CE/Federal Communications Commission (FCC)
ELKO Internal Logistics Data
Shipping Box Weight
0.6 kg
Shipping Box Height
5 cm
Shipping Box Depth
21 cm
Shipping Box Width
15 cm
ELKO Verified Logistics Data
Unit Width
15 cm
Unit Depth
21 cm
Unit Height
5 cm

Industrial Modbus Gateway for Modern IIoT Connectivity
The IMG-3105AT is designed to bridge Modbus TCP, Modbus RTU, and Modbus ASCII networks for modern industrial automation and IIoT applications. It enables seamless communication between Ethernet-based control systems and legacy serial devices, allowing existing PLCs, RTUs, HMIs, power meters, sensors and industrial controllers to be integrated into IP networks without replacing field equipment. By preserving existing Modbus infrastructures while extending network connectivity, the IMG-3105AT provides an efficient migration path for factories, transportation systems, utilities and building automation toward digitalized industrial environments.

MQTT Edge Gateway for Data Aggregation and Distribution
The IMG-3105AT expands traditional Modbus gateway functionality by integrating both MQTT Client and built-in MQTT Broker capabilities. It collects data from Modbus RTU/ASCII devices and securely publishes MQTT messages to SCADA systems, MES platforms, edge servers, or cloud services. The embedded MQTT Broker also enables local message exchange without requiring an external broker, simplifying Industrial IoT deployment.

In addition to MQTT communication, the IMG-3105AT bridges Modbus TCP/IP and Modbus RTU/ASCII networks, allowing legacy serial devices to be easily integrated into Ethernet-based automation systems. It supports up to 32 TCP slave connections in Master mode and 32 TCP master connections in Slave mode, providing a flexible and reliable solution for industrial hybrid networks.

Flexible Modbus Operation Modes
The IMG-3105AT supports four Modbus communication modes, including RTU Master, RTU Slave, ASCII Master, and ASCII Slave. These operation modes provide flexible deployment for various industrial control architectures and simplify communication between Modbus TCP networks and serial Modbus devices. Whether operating as a master or slave, the gateway enables reliable protocol conversion, centralized monitoring and seamless integration of legacy Modbus equipment into modern Ethernet infrastructures.

Secure Remote Management and Cybersecurity
The IMG-3105AT provides comprehensive remote management through web-based interfaces, SNMP and CloudNMS monitoring, allowing administrators to remotely configure, monitor and maintain devices with ease. To strengthen cybersecurity, the gateway supports Secure Boot, SNMP v1/v2c/v3, MQTT over TLS, firmware upgrade, configuration backup and restore, user authentication, and secure management mechanisms. Event Log, Syslog, SNMP Trap and Relay Alarm functions further simplify maintenance while improving system availability and operational reliability.

Stable Performance under Harsh Industrial Environments
Designed for demanding industrial applications, the IMG-3105AT features a rugged IP30-rated metal enclosure, wide operating temperature range from -40 to 75°C, redundant 9~48V DC / 24V AC power inputs with automatic failover, surge protection and ESD immunity. Supporting both DIN-rail and wall-mount installation, the gateway ensures stable and continuous Modbus communication in factories, transportation systems, power substations and other mission-critical industrial environments.

Dual Power Input for High Availability Network Systems
The IMG-3105AT features a redundant dual power input design supporting 9V to 48V DC operation for enhanced system reliability. When the primary power source fails, the built-in hardware failover mechanism automatically switches to the backup supply, ensuring uninterrupted communications and continuous operation. This high-availability design is especially suitable for remote sites, process control systems and mission-critical industrial applications where maintaining network uptime is essential.

PLANET CloudNMS – Cloud-Based Universal Network Management
PLANET’s CloudNMS platform and mobile app empower IT staff to remotely manage all network devices and Powered Devices (PDs) in real time. Designed for enterprises and industries, CloudNMS minimizes the need for on-site troubleshooting by providing centralized monitoring, fault detection, and instant alerts.

With CloudNMS, businesses can manage diverse network deployments more efficiently, securely, and intelligently—all from a single cloud-based platform.

  • Supports asynchronous serial data rates up to 921600bps
  • Supports RTU Master mode
  • Supports RTU Slave mode
  • Supports ASCII Master mode
  • Supports ASCII Slave mode
  • Supports protocol conversion between Modbus TCP and Modbus RTU/ASCII
  • Supports up to 32 TCP slave connections in Master mode
  • Supports up to 32 TCP master connections in Slave mode
  • Supports MQTT Client and built-in MQTT Broker functions
  • Supports Transparent Publish, Topic Distribution and Transparent Subscribe mechanisms

Specificațiile, imaginile și echipamentele pot fi modificate de către producător fără notificare prealabilă.